Electric Autoclave - EA 6 series

Pressure vessel used for vulcanising precured treads to the casings.

Features

  • Designed to ASME specifications.
  • Differential pressure system (DPS/DPC/MEP) as standard.
  • Capacity - 2 to 24 casings (based on 315/80R22.5).
  • Suitable for casings with diameters from 700 mm to 1300 mm.
  • PLC control for accuracy and uniform repeatability.
  • Specially designed forced air circulation system for uniform temperature.
  •  Accurate temperature control with 3 independent temperature sensors.
  • Wide range of optional equipment.
  • ASME compliance certificate or stamping (or other national certificates as appropriate) on request.
Electric Autoclave ortho views
Electric Autoclave ortho views

EA 6-3 07/60

Technical Data

Model
EA 6-2 02/60
EA 6-3 02/60
EA 6-2 04/60
EA 6-3 04/60
EA 6-2 07/60
EA 6-3 07/60
EA 6-2 11/60
EA 6-3 11/60
EA 6-2 24/60
EA 6-3 24/60
Number of Tyres (based on 12.00-24.00 or 315/80R22.5)
2
4
7
11
24
Catalogue No.

MC56 62 - AX*

MC56 63 - AX*

MC56 62 - BX*

MC56 63 - BX*

MC56 62 - CX*

MC56 63 - CX*

MC56 62 - DX*

MC56 63 - DX*

MC56 62 - FX*

MC56 63 - FX*

Dimensions (L x W x H) (mm / in)
3900 x 1900 x 2100
153.5 x 74.8 x 82.6
4650 x 1900 x 2100
183.0 x 74.8 x 82.6
5650 x 1900 x 2100
222.4 x 74.8 x 82.6
7800 x 1900 x 2100
307.0 x 74.8 x 82.6
12100 x 1900 x 2100
476.3 x 74.8 x 82.6
Air pressure (kg/cm² / psi)
8.0-10.0 / 114-142
Total installed power (kW / hp)
15.75 / 21.0
25.5 / 34.0
25.5 / 34.0
43.5 / 58.0
87.0 / 116.0
* X in Cat. No. denotes power supply specifications (V / Hz / ph)
R - 220 / 60 / 3
O - 380 / 50 / 3
S - 380 / 60 / 3
P - 415 / 50 / 3
U - 440 / 60 / 3
Auxiliary voltage
24 V-DC
Weight (kg / lb)
1800 / 3970
2700 / 5950
3600 / 7940
4400 / 9700
8000 / 17650
Max. operating temp. (ºC / ºF)
125 / 257
Maximum tyre diameter (mm / in)
1300 / 51.2
Minimum tyre diameter (mm / in)
700 / 27.5
Maximum section width (mm / in)
470 / 18.5
Minimum section width (mm / in)
140 / 5.5
Maximum bead diameter (in)
24.5
Minimum bead diameter (in)
14.0
Maximum bead width (in)
14.0
Minimum bead width (in)
4.0
Rupture disc
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
Control system
Digital PLC
Analogue PLC
Digital PLC
Analogue PLC
Digital PLC
Analogue PLC
Digital PLC
Analogue PLC
Digital PLC
Analogue PLC
Automatic control system to prevent door opening before cycle completion
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes

Optional Accessories

Cure law cycle recorder
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Facility for remote monitoring, data logging and email alerts
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes

Note: Autoclave will be supplied without ASME certification/documentation. Country specific requirements (ASME certification, “U” Stamp, NR13, etc.) to be specified at the time of ordering and will be available only for EA 6-3.

Warranty against manufacturing defects is applicable for a period of 6 months from the date of commissioning or 9 months from the date of invoice whichever is earlier, while the bought electrical pneumatic items, etc will not be covered by the manufacturers warranty. Warranty is limited to repair or replacement of defective parts and does not extend to any consequential liability there of.